TransFactor NFATc1 Chemiluminescent Kit

TransFactor NFATc1 Chemiluminescent Kit

Brand: Takara Bio.
In stock
SKU
TransFactor NFATc1 Chemiluminescent Kit
Grouped product items
Product Name Size
TransFactor NFATc1 Chemiluminescent Kit
SKU: 631955
2 Plates
Make An Enquiry
× Product Enquiry
TransFactor NFATc1 Chemiluminescent Kit
TransFactor NFATc1 Chemiluminescent Kit

Fill in the details below:

TransFactor Chemiluminescent Kits provide rapid, sensitive detection of specific transcription factor DNA binding in whole cell or nuclear extracts using an ELISA (enzyme-linked immunosorbent assay) format. Each NFATc1 Chemiluminescent Kit contains two 96-well plates with the consensus binding sequence for NFATc1 coated in the wells. Primary and Secondary Antibodies are provided to detect the bound transcription factor. Competitor Oligos are provided for competition assays.

Overview

  • Highly sensitive detection of DNA-transcription factor interactions
  • Faster and more sensitive than gel-shift assays
  • Nonradioactive, chemiluminescent detection in a flexible, high-throughput format
  • Compatible with nuclear, whole-cell, and cytosolic extracts

Applications

  • Monitor signal transduction
  • Perform multiple experiments in 3–4 hours, without the need for radioactive labeling
  • Study DNA-NFATc1 transcription factor interactions
  • Examine NFATc1 behavior in a cell line that has been treated with different stimuli
  • Compare the relative amounts of the transcription factor NFATc1 in different cell types

TransFactor Chemiluminescent Kits detect DNA-transcription factor binding activities in as little as 10 ng of cellular extract

TransFactor Chemiluminescent Kits detect DNA-transcription factor binding activities in as little as 10 ng of cellular extract

TransFactor Chemiluminescent Kits detect DNA-transcription factor binding activities in as little as 10 ng of cellular extract. The activity of NFκB p65 was assessed using the TransFactor Chemiluminescent NFκB Family Kit. NFκB p65 activity was tested using increasing amounts of nuclear extracts (Panel A) or whole-cell extracts (Panel B) from uninduced and TNF-α induced HeLa cells. Chemiluminescent signals were detected with the Monolight 3096 Microplate Luminometer.

Write Your Own Review
You're reviewing:TransFactor NFATc1 Chemiluminescent Kit
Your Rating

TransFactor Chemiluminescent Kits provide rapid, sensitive detection of specific transcription factor DNA binding in whole cell or nuclear extracts using an ELISA (enzyme-linked immunosorbent assay) format. Each NFATc1 Chemiluminescent Kit contains two 96-well plates with the consensus binding sequence for NFATc1 coated in the wells. Primary and Secondary Antibodies are provided to detect the bound transcription factor. Competitor Oligos are provided for competition assays.

Overview

  • Highly sensitive detection of DNA-transcription factor interactions
  • Faster and more sensitive than gel-shift assays
  • Nonradioactive, chemiluminescent detection in a flexible, high-throughput format
  • Compatible with nuclear, whole-cell, and cytosolic extracts

Applications

  • Monitor signal transduction
  • Perform multiple experiments in 3–4 hours, without the need for radioactive labeling
  • Study DNA-NFATc1 transcription factor interactions
  • Examine NFATc1 behavior in a cell line that has been treated with different stimuli
  • Compare the relative amounts of the transcription factor NFATc1 in different cell types

TransFactor Chemiluminescent Kits detect DNA-transcription factor binding activities in as little as 10 ng of cellular extract

TransFactor Chemiluminescent Kits detect DNA-transcription factor binding activities in as little as 10 ng of cellular extract

TransFactor Chemiluminescent Kits detect DNA-transcription factor binding activities in as little as 10 ng of cellular extract. The activity of NFκB p65 was assessed using the TransFactor Chemiluminescent NFκB Family Kit. NFκB p65 activity was tested using increasing amounts of nuclear extracts (Panel A) or whole-cell extracts (Panel B) from uninduced and TNF-α induced HeLa cells. Chemiluminescent signals were detected with the Monolight 3096 Microplate Luminometer.

Write Your Own Review
You're reviewing:TransFactor NFATc1 Chemiluminescent Kit
Your Rating