Capturem Protein A 24-Well Plate - High Capacity

Capturem Protein A 24-Well Plate - High Capacity

Brand: Takara Bio.
In stock
SKU
Capturem Protein A 24-Well Plate - High Capacity

Rapid protein A-based antibody purification in a 24-well format. 5-15 min, RT protocol.

Grouped product items
Product Name Size
Capturem™ Protein A 24-Well Plate - HC
SKU: 635742
4 x 24-well plate
Make An Enquiry
× Product Enquiry
Capturem Protein A 24-Well Plate - High Capacity
Capturem Protein A 24-Well Plate - High Capacity

Fill in the details below:

Rapid Capturem Protein A-based antibody purification

The Capturem Protein A 24-Well Plate - HC is a high-capacity, single-use, disposable plate for the simple, rapid purification of antibodies. Up to 4.3 ml of sample can be loaded per well. This plate is suitable for purification of antibodies from animal serum, ascites fluid, cell culture supernatant of hybridoma cell lines, and other sources.

Overview

  • No-waiting workflow: 5–15-minute, room-temperature protocol
  • High purity: small column bed volumes trap fewer contaminants and allow large-volume washes
  • High concentration: extremely small elution volumes yield highly concentrated antibodies
  • High quality: short residence times reduce the possibility of aggregation or loss of activity
  • Versatile: purify a wide range of antibodies

Applications

  • Antibody purification
  • Antibody screening
  • Immunoprecipitation and co-immunoprecipitation (For a complete IP solution, see Capturem IP & Co-IP Kit)
  • Approximate yields for Capturem Protein A formats

Capturem Protein A- or G-functionalized membranes

Capturem Protein A- or G-functionalized membranes

Antibody purification workflow for Capturem Protein A or G 96-well plates. Each well can be loaded with up to 850 µl of a diluted sample (antibody sample diluted from 1:1 to 1:20 with buffer). Following binding, the membrane is then washed and the bound antibiody eluted with the appropriate buffers. Note: Protocol time varies for each format. Check user manuals for specifics on protocol times.

Capturem spin columns and filtration devices

Capturem spin columns and filtration devices

Available Capturem spin column and filtration device formats. Pictured from left to right: nanoprep, miniprep, 96-well, 24-well, maxiprep, and large-volume Capturem formats. Formats available vary for the different functionalized membranes. Check product pages for list of available formats.

Load volumes and approximate yields for available Capturem formats by chemistry

Load volumes and approximate yields for available Capturem formats by chemistry

Load volumes and yields of Capturem purification formats.

Write Your Own Review
You're reviewing:Capturem Protein A 24-Well Plate - High Capacity
Your Rating

Rapid Capturem Protein A-based antibody purification

The Capturem Protein A 24-Well Plate - HC is a high-capacity, single-use, disposable plate for the simple, rapid purification of antibodies. Up to 4.3 ml of sample can be loaded per well. This plate is suitable for purification of antibodies from animal serum, ascites fluid, cell culture supernatant of hybridoma cell lines, and other sources.

Overview

  • No-waiting workflow: 5–15-minute, room-temperature protocol
  • High purity: small column bed volumes trap fewer contaminants and allow large-volume washes
  • High concentration: extremely small elution volumes yield highly concentrated antibodies
  • High quality: short residence times reduce the possibility of aggregation or loss of activity
  • Versatile: purify a wide range of antibodies

Applications

  • Antibody purification
  • Antibody screening
  • Immunoprecipitation and co-immunoprecipitation (For a complete IP solution, see Capturem IP & Co-IP Kit)
  • Approximate yields for Capturem Protein A formats

Capturem Protein A- or G-functionalized membranes

Capturem Protein A- or G-functionalized membranes

Antibody purification workflow for Capturem Protein A or G 96-well plates. Each well can be loaded with up to 850 µl of a diluted sample (antibody sample diluted from 1:1 to 1:20 with buffer). Following binding, the membrane is then washed and the bound antibiody eluted with the appropriate buffers. Note: Protocol time varies for each format. Check user manuals for specifics on protocol times.

Capturem spin columns and filtration devices

Capturem spin columns and filtration devices

Available Capturem spin column and filtration device formats. Pictured from left to right: nanoprep, miniprep, 96-well, 24-well, maxiprep, and large-volume Capturem formats. Formats available vary for the different functionalized membranes. Check product pages for list of available formats.

Load volumes and approximate yields for available Capturem formats by chemistry

Load volumes and approximate yields for available Capturem formats by chemistry

Load volumes and yields of Capturem purification formats.

Write Your Own Review
You're reviewing:Capturem Protein A 24-Well Plate - High Capacity
Your Rating